CGXFY - RECHARGEABLE BATTERIES,97-01-UH-B,(NI-CD SEALED)
- MSDS: CGXFY
- Manufacturer: POWER SONIC CORP
- Product Name: RECHARGEABLE BATTERIES,97-01-UH-B,(NI-CD SEALED)
- National Stock Number: 6135-01-341-9814
Product Identification
Product ID:RECHARGEABLE BATTERIES,97-01-UH-B,(NI-CD SEALED)
MSDS Date:01/02/1991
FSC:6135
NIIN:01-341-9814
MSDS Number: CGXFY
Responsible Party
REDWOOD CITY, CA 94063-3929
US
Emergency Phone: 650-364-5001
Info Phone: 650-364-5001
Cage: 56309
Contractor
Telephone: 650-364-5001
Cage: 56309
Ingredients
CADMIUM AND CADMIUM HYDROXIDE
Fraction By Weight: 13-16%
OSHA PEL 0.1 MG CD/M3 FUME
ACGIH TLV: 0.05 MG CD/M3 FUME
NICKEL AND NICKEL HYDROXIDE
Fraction By Weight: 20-30%
OSHA PEL 0.1 MG NI/M3
ACGIH TLV: 0.1 MG NI/M3
POTASSIUM HYDROXIDE OR SODIUM HYDROXIDE
RTECS: 9999999ZZ
Fraction By Weight: 2-4%
COBALT HYDROXIDE
RTECS: 9999999ZZ
Fraction By Weight: 0.5-1%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:PRODUCT POSES HEALTH HAZARD ONLY IF
OUTER CASE IS RUPTURED OR LEAKING. IF LEAKING: EYES/SKIN: POTASSIUM
HYDROXIDE AND/OR SODIUM HYDROXIDE WILL BURN TISSUE. DERMATITIS MAY
OCCUR WITH SKIN. INHALATION: CD-POSSIBLE LUNG OR KIDNEY DAMAGE;
NI-POSSIBLE LUNG DAMAGE. INGESTION: STOMACH IRRITATION.
Explanation of Carcinogenicity:NONE OF PRODUCT'S INGREDIENTS ARE LISTED
BY NTP, IARC, OSHA.
Effects of Overexposure:EYES: IRRITATION, BURNING SENSATION. SKIN:
IRRITATION, BURNING SENSATION, DERMATITIS. INHALATION: LUNG AND
KIDNEY DAMAGE. INGESTION: STOMACH IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER. GET MEDICAL
ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING. WASH SKIN WITH LARGE
VOLUME OF WATER; MILD ACID MAY BE USED TO NEUTRALIZE. GET MEDICAL
ATTENTION IF NECESSARY. INHALATION: MOVE TO FRESH AIR. GET MEDICAL
ATTENTION. INGESTION: GET MEDICAL ATTENTION.
Fire Fighting
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER.
Fire Fighting Procedures:IF INCINERATED USE NIOSH/MSHA APPROVED
POSITIVE PRESSURE SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:TOXIC CADMIUM OXIDE FUMES MAY BE RELEASED
DURING BURNING.
Accidental Release
Spill Release Procedures:FLUSH ELECTROLYTE SPILLS WITH WATER. DO NOT
BREAK OPEN BATTERY CELL.
Neutralizing Agent:MILD ACID MAY BE USED TO NEUTRALIZE.
Handling
Handling and Storage Precautions:PROTECT AGAINST CRACKING OF CASE
MATERIAL. PROVIDE ADEQUATE VENTLATION. ADHERE TO PROPER CHARGING
PROCEDURE.
Other Precautions:DO NOT BREAK OPEN BATTERY CELL DURING MAINTENANCE OF
CONTAMINATED EQUIPMENT.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED SELF-CONTAINED BREATHING
APPARATUS (IF BURNED).
Ventilation:PROTECT AGAINST CRACKING OF CASE MATERIAL. ADHERE TO PROPER
CHARGING PROCEDURE.
Protective Gloves:NEOPRENE OR PVC IF CELL BROKEN OPEN.
Eye Protection:CHEMICAL GOGGLES IF CELL BROKEN OPEN.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EACH BATTERY CELL IS A SEALED CYLINDRICAL CONTAINER ENCLOSING A CADMIUM
ELECTRODE, NICKEL ELECTRODE AND POTASSIUM HYDROXIDE OR SODIUM
HYDROXIDE ELECTROLYTE.
Chemical Properties
HCC:N1
Appearance and Odor:EACH BATTERY CELL IS A SEALED CYLINDRICAL
CONTAINER.
Stability
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:TOXIC FUMES MAY BE RELEASED IF
INCINERATED.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH APPLICABLE LOCAL,
STATE AND FEDERAL REGULATIONS. DO NOT INCINERATE OR MUTILATE; DO
NOT SHORT CIRCUIT-MAY CAUSE BURNS. DISPOSE OF ALL WASTES IN
ACCORDANCE WITH LOCAL, STAT E AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.